Free practice questions on Measurements, chapter 29 of the SARL's Class A manual, for South Africa's Radio Amateur Examination (RAE). Every question has the right answer and an explanation. Sections covered:

  • 29.1 The ammeter
  • 29.2 The voltmeter
  • 29.3 The multimeter
  • 29.4 Frequency counter
  • 29.5 Power and SWR meter
  • 29.6 The oscilloscope
  • 29.7 Marker generator
  • 29.8 The dip meter
  • 29.9 The dummy load
  • 29.10 The field strength meter
  • 29.11 The absorption wavemeter
  • 29.12 The two-tone signal generator

85 questions

  1. 1. In a moving-coil meter, what turns the coil and the pointer fixed to it?
    Show answer

    Its coil’s magnetic field pushing against the magnet’s field

    Current in the coil sets up a magnetic field that acts against the field of the U-shaped permanent magnet, so the coil pivots on its bearings. Heating drives other kinds of meter, not this one.

  2. 2. Which is the basic instrument for measuring both current and voltage?
    Show answer

    The moving-coil meter

    A moving-coil meter reads current directly, more with a shunt, and voltage with a series multiplier. An oscilloscope shows voltage against time, but it is not the basic meter for current.

  3. 3. Before you can work out the shunt that extends a meter movement’s current range, which two facts about the movement must you know?
    Show answer

    Its full-scale current and its internal resistance

    RS = RM ÷ (n − 1) needs the movement’s resistance RM, and its full-scale current to find the scale factor n. The resistance of the circuit being measured does not enter the sum.

  4. 4. To make an ammeter read larger currents than it was designed for, where does the extra resistor go?
    Show answer

    In parallel with the meter movement

    The shunt goes across the movement, so most of the current flows past it and only a small part through it. A resistor across the circuit being tested would only add to the current being measured.

  5. 5. How is an ammeter connected to measure the current through a lamp?
    Show answer

    In series with the lamp, so that its current flows through the meter

    An ammeter must carry the current it measures, so it goes in series with the lamp. Connected across the lamp, its very low resistance would short the lamp out and carry far too much current.

  6. 6. Why should an ammeter’s own resistance be kept as low as possible?
    Show answer

    So that it barely changes the current it is measuring

    An ammeter is in series, so any resistance it has adds to the circuit’s and lowers the current it measures. Drawing little current is the voltmeter’s reason for a high resistance.

  7. 7. A meter movement reads 1 mA at full scale and has a resistance of 90 Ω. What shunt makes it read 4 mA at full scale?
    Show answer

    30 Ω

    n = 4 mA ÷ 1 mA = 4, so RS = RM ÷ (n − 1) = 90 ÷ 3 = 30 Ω. Dividing by n gives 22,5 Ω, which takes too much current, so the meter reads low.

    Try it: Ohm's Law & Power
  8. 8. A 1 mA meter movement is fitted with a shunt so that it reads 5 mA at full scale. At full scale, how much current flows through the shunt?
    Show answer

    4 mA

    The shunt carries the current the movement cannot: 5 − 1 = 4 mA, while 1 mA flows in the movement. The whole 5 mA flows only in the leads to the meter.

    Try it: Ohm's Law & Power
  9. 9. A 200 µA meter movement with a resistance of 390 Ω must read 1 mA at full scale. Which is nearest to the shunt it needs?
    Show answer

    100 Ω

    n = 1 mA ÷ 200 µA = 5, so RS = 390 ÷ (5 − 1) = 97,5 Ω, nearest 100 Ω. 80 Ω is close to 390 ÷ 5 = 78 Ω: n used instead of n − 1.

    Try it: Ohm's Law & Power
  10. 10. What does the manual call ammeters made for small currents?
    Show answer

    Milliammeters and microammeters

    Ammeters for small currents are milliammeters (thousandths of an ampere) and microammeters (millionths). A megohmmeter measures very high resistance, such as insulation, not current.

  11. 11. How is a sensitive ammeter turned into a voltmeter?
    Show answer

    With a multiplier resistor in series with it

    A multiplier in series drops the voltage the movement cannot take, so full-scale current flows at the chosen voltage. Connected straight across a circuit, the bare movement would carry far more than its full-scale current.

  12. 12. A 20 µA meter movement is to read up to 2,5 kV, the supply of a valve amplifier. What does it need?
    Show answer

    A series resistor of about 125 MΩ

    R = V ÷ I = 2 500 V ÷ 20 µA = 125 MΩ in series to drop the voltage; the movement’s resistance is negligible. 125 kΩ takes µA for mA; a shunt only extends the current range.

    Try it: Ohm's Law & Power
  13. 13. How is a voltmeter connected to measure the voltage dropped by a resistor?
    Show answer

    Across the resistor, in parallel with it

    A voltmeter reads the potential difference between two points, so it goes across the resistor, in parallel. In series its high resistance would be added to the circuit and starve it of current.

  14. 14. Why should a voltmeter’s resistance be as high as possible?
    Show answer

    So that it takes very little current and barely upsets the circuit

    In parallel, a voltmeter takes some current from the circuit; the higher its resistance, the less it loads the circuit and the truer the reading. Carrying the circuit’s current is an ammeter’s job.

  15. 15. A transistorised (FET) multimeter is more sensitive on its voltage ranges than an older analogue voltmeter. What does that mean for the circuit under test?
    Show answer

    It sees a much higher input resistance, so it is loaded less

    A FET input draws almost no current, so the meter shows the circuit an input resistance of many megohms and barely loads it. A meter drawing more current would load it more, not less.

  16. 16. Two 100 kΩ resistors in series sit across a 12 V supply. What does a voltmeter with a resistance of 100 kΩ read across the lower one?
    Show answer

    4 V

    With the meter in parallel, the lower arm is 100 kΩ and 100 kΩ in parallel = 50 kΩ, so it reads 12 × 50 ÷ 150 = 4 V. 6 V is the voltage without the meter: loading ignored.

    Try it: Voltage Divider
  17. 17. A 1 mA meter movement drops 0,5 V at full scale. What multiplier resistor makes it read 2 V at full scale?
    Show answer

    1,5 kΩ

    The multiplier must drop the 2 − 0,5 = 1,5 V the movement cannot take, at the full-scale 1 mA: R = 1,5 V ÷ 1 mA = 1,5 kΩ. 2 kΩ forgets the movement’s own 0,5 V.

    Try it: Ohm's Law & Power
  18. 18. A voltmeter is often rated in ohms per volt of full-scale range. What is that figure for a meter built on a 200 µA movement?
    Show answer

    5 kΩ per volt

    Each volt of range needs R = 1 V ÷ 200 µA = 5 kΩ, so the rating is 1 ÷ full-scale current = 5 kΩ per volt. 200 kΩ per volt would need a far more sensitive 5 µA movement.

    Try it: Ohm's Law & Power
  19. 19. A simple rectifier-type AC voltmeter reads correctly on a sine wave. Why can it read wrongly on a square wave?
    Show answer

    It responds to the rectified average; its scale assumes a sine

    Simple rectification makes the movement respond to the average, and the scale is marked so that a pure sine reads its RMS value; other waveforms have another average-to-RMS ratio. A true RMS response would suit any waveform.

  20. 20. Why does a meter movement need a rectifier before it can read AC?
    Show answer

    It is a DC instrument: AC would push its pointer each way in turn

    A moving-coil movement is designed for DC: its turning force follows the direction of the current, so on AC the pointer barely moves. AC flows through the coil easily; the pointer simply cannot follow it.

  21. 21. Which three quantities can every multimeter measure?
    Show answer

    Voltage, current and resistance

    A multimeter measures voltage, current and resistance, chosen with its mode switch; some models add capacitance and more. Capacitance is an extra, and current is never left out.

  22. 22. On an older multimeter, you measure a 1,5 V cell with the meter set to its 500 V range. What will you see?
    Show answer

    Too little deflection to read

    1,5 V is only 0,3 % of a 500 V range, so the pointer barely moves and cannot be read. Overload damage is the risk of the opposite mistake, a range far too low.

  23. 23. What can happen if an older multimeter set to its 2,5 V range is used to measure a 50 V supply?
    Show answer

    The overload may damage the meter

    50 V is twenty times the 2,5 V full scale, so far more current than the movement can take flows through it. Too little deflection is what a range far too high gives.

  24. 24. What does the buzzer on some multimeters let you do?
    Show answer

    Test continuity without looking at the meter

    The buzzer sounds when the probes find an unbroken path, so you can check continuity with your eyes on the circuit. It is not an overload alarm.

  25. 25. By the manual, which setting do modern multimeters choose for themselves, unlike older ones?
    Show answer

    The full-scale range for each reading

    Modern meters select the appropriate scale automatically, but the user still chooses the function with the mode switch. On older meters both are set by hand.

  26. 26. A frequency counter counts 50 700 cycles while its gate is open for 10 ms. What frequency does it show?
    Show answer

    5,07 MHz

    Frequency = count ÷ gate time = 50 700 ÷ 0,01 s = 5,07 MHz. Taking the count itself as the frequency, as if the gate were open for 1 s, gives 50,7 kHz, a hundred times too low.

  27. 27. A frequency counter’s gate stays open for 10 ms. What is the smallest step by which its reading can change?
    Show answer

    100 Hz

    One count more or less in 10 ms is a step of 1 ÷ 0,01 s = 100 Hz, so a longer gate gives finer resolution. 0,01 Hz mistakes the gate time itself for the step.

    Try it: Frequency ↔ Wavelength
  28. 28. A frequency counter has a nine-digit display. What mainly decides how close its readings are to the true frequency?
    Show answer

    Its internal reference oscillator

    The reference oscillator times the counting period, so any error in it appears in every reading, however many digits are shown. More digits give finer resolution, not more accuracy.

  29. 29. A home-built counter times its counting period with a simple LC oscillator. What error might its readings have?
    Show answer

    Several percent

    An LC oscillator is far less stable than a crystal, so a counter timed by one may be several percent out; with a crystal it can be very accurate. Counting is exact only if the counting time is.

  30. 30. A cheap frequency counter may read up to 3 % out. Which is nearest to how far its reading of a 14,2 MHz signal could be wrong?
    Show answer

    400 kHz

    3 % of 14,2 MHz is 0,03 × 14 200 kHz = 426 kHz, nearest 400 kHz: enough to put you outside a band. 40 kHz slips a decimal place.

  31. 31. In an amateur station, what job does a reflectometer do?
    Show answer

    Checking the SWR on a feedline

    An SWR meter is also called a reflectometer because it measures reflected power, which with the forward power gives the SWR. The manual prefers “SWR meter”, since the word also names tools in optics.

  32. 32. From which two readings does an SWR meter work out the SWR?
    Show answer

    The forward power and the reflected power

    An SWR meter measures the power going out towards the antenna and the power coming back, and works out the SWR from their ratio. The DC input power says nothing about the match.

  33. 33. An SWR meter shows 100 W forward and 10 W reflected power. If the feedline has no loss, how much power does the antenna take?
    Show answer

    90 W

    The antenna takes what goes forward less what comes back: 100 − 10 = 90 W. Reading the forward figure alone, 100 W, ignores the power reflected at the mismatch.

    Try it: SWR / VSWR & Return Loss
  34. 34. Why does it matter whether a wattmeter reads average or peak power when it measures SSB speech?
    Show answer

    Speech peaks sit far above its average, so the two readings differ

    The human voice has peaks far above its average, and an SSB or AM signal follows it, so peak and average readings differ greatly. An average reading is lower than the peak, never higher.

  35. 35. On which mode does a transmitter’s output power stay the same, however loud the speech?
    Show answer

    FM

    FM varies the frequency, not the amplitude, so the output stays constant whatever the modulating signal. AM, SSB and DSB output all rise and fall with the voice.

  36. 36. An antenna analyser at the antenna shows a purely resistive 25 Ω. If the feedline is 50 Ω coax, what SWR does it read?
    Show answer

    2:1

    SWR is the ratio of the line impedance to the load, written as 1 or more: 50 ÷ 25 = 2:1. 0,5:1 has the ratio upside down; an SWR is never below 1:1.

    Try it: SWR / VSWR & Return Loss
  37. 37. Near a strong broadcast station, an antenna analyser shows a much higher SWR than expected. Why?
    Show answer

    It takes the strong signal picked up by the antenna as reflected power

    The analyser’s own oscillator is very weak, so strong signals coming down the feedline look to it like reflected power; its frequency is not pulled. The manual suggests more power, or a selective voltmeter that rejects them.

  38. 38. By the manual, why may an antenna analyser be used on frequencies outside the amateur bands?
    Show answer

    Its built-in oscillator is so weak that this is allowed

    The analyser’s internal oscillator puts out so little power that the manual calls its use legal outside the amateur allocations. Connected to an antenna, its weak signal is radiated, just very little of it.

  39. 39. On an oscilloscope set to 0,5 ms/div, one cycle of a sine wave spans 4 divisions. What is its frequency?
    Show answer

    500 Hz

    Period = divisions × time per division = 4 × 0,5 ms = 2 ms, and f = 1 ÷ t = 1 ÷ 0,002 s = 500 Hz. 2 kHz leaves out the 4 divisions.

    Try it: Frequency ↔ Wavelength
  40. 40. An oscilloscope is set to 2 V/div. A sine wave spans 6 divisions from its lowest point to its highest (peak-to-peak). What is its RMS voltage?
    Show answer

    4,24 V

    6 divisions × 2 V = 12 V peak-to-peak, so the peak is 6 V and VRMS = 6 ÷ 1,414 = 4,24 V. 8,49 V forgets to halve the peak-to-peak value first.

  41. 41. On an oscilloscope set to 5 V/div, a sine wave’s peaks reach 2,6 divisions above the centre line. Which is nearest to its RMS voltage?
    Show answer

    9 V

    The peak is 2,6 × 5 = 13 V, and VRMS = 13 ÷ 1,414 = 9,19 V, nearest 9 V. Taking the 13 V peak as the RMS value is the usual slip.

  42. 42. In an analogue oscilloscope, what does the time-base do?
    Show answer

    Sweeps the dot across steadily, then returns it very quickly

    The time-base drives the X plates with a smoothly rising voltage, sweeping the dot from left to right at the chosen rate before it returns quickly. Up and down movement comes from the input, through the Y amplifier.

  43. 43. The vertical deflection of an oscilloscope trace shows which quantity of the input signal?
    Show answer

    Its voltage

    The Y plates are driven by the input voltage, through the Y amplifier, so the height of the trace is voltage, calibrated in V/div. A current shows only as the voltage it drops across a resistor.

  44. 44. Which test instrument has amplifiers for both its horizontal and its vertical deflection?
    Show answer

    The oscilloscope

    An oscilloscope has a horizontal (X) channel driven by the time-base and a vertical (Y) amplifier for the input signal. A multimeter’s pointer moves one way only and needs no such channels.

  45. 45. Why does a repeating waveform stand still on an oscilloscope screen instead of drifting across it?
    Show answer

    A trigger circuit starts each trace at the same point of the wave

    The trigger circuit starts each sweep when the input reaches a set voltage, so every cycle is drawn over the last and the picture appears still. The glow of the screen fades within moments.

  46. 46. Of these, which instrument would you choose to check the quality of a CW or SSB transmitter’s signal?
    Show answer

    A monitor oscilloscope

    A monitor oscilloscope shows the transmitted waveform itself, so poor keying or flat-topping can be seen; a field strength meter shows only that RF is present. A spectrum analyser, not offered here, does better still.

  47. 47. To view an AM transmitter’s modulation envelope on an older CRT oscilloscope, where is the RF sample usually taken from?
    Show answer

    The final amplifier’s output, by a small pick-up loop

    The envelope exists only once the RF is modulated, so a small loop held near the final tuned circuit feeds a sample to the vertical plates. The driver’s RF carries no modulation yet.

  48. 48. Why is an oscilloscope used instead of a pointer meter to look at RF waveforms and modulation?
    Show answer

    A pointer meter is far too slow to follow such rapid changes

    A meter’s pointer has too much inertia to keep up with fast-changing signals, while an oscilloscope draws the waveform itself against time. RF does not burn out a meter; the pointer simply cannot follow it.

  49. 49. How does a modern oscilloscope differ inside from the old CRT type?
    Show answer

    A microprocessor digitises the signal for display

    A digital oscilloscope samples the input with a microprocessor and shows it on a screen, or on a computer or phone, with controls much like the old type. It shows any waveform, not only digital ones.

  50. 50. Which description fits a marker generator?
    Show answer

    A crystal oscillator whose harmonics fall at known, even steps

    A marker generator is a crystal oscillator designed to produce harmonics, giving “markers” at fixed steps such as every 100 kHz across HF. A swept oscillator has no fixed, accurately known frequencies to mark anything by.

  51. 51. Why is a marker generator built around a crystal oscillator?
    Show answer

    So that its markers fall on accurately known frequencies

    A crystal holds its frequency very accurately, so every harmonic lands on a known frequency and can be used to check a receiver’s dial. A crystal oscillator is fixed in frequency; it cannot be tuned across a band.

  52. 52. With a marker generator you find the 14 MHz marker, count two 100 kHz markers above it, then three 10 kHz markers above that, where the signal is. How far above 14 MHz is the signal?
    Show answer

    230 kHz

    Two 100 kHz markers make 200 kHz and three 10 kHz markers 30 kHz more: 230 kHz above 14 MHz, at 14,23 MHz. Swapping the two counts gives 320 kHz.

  53. 53. A marker generator is switched to give markers every 100 kHz. On which of these frequencies will you hear one?
    Show answer

    7,100 MHz

    Markers fall on every multiple of 100 kHz: 7 100 kHz is the 71st harmonic. 7,150 MHz lies halfway between two markers and would need markers every 50 kHz.

  54. 54. Why are marker generators now rarely needed?
    Show answer

    Modern transceivers almost all have accurate digital frequency readouts

    Almost all modern transceivers show their frequency accurately on a digital readout, and frequency counters are freely available, so markers are seldom needed. Their signals are as easy to hear as ever, and no law bans them.

  55. 55. At heart, what kind of instrument is a dip meter?
    Show answer

    A tunable RF oscillator: a small signal generator

    A dip meter is a variable-frequency LC oscillator with its coil outside the case, so it is a small RF signal generator. It sends out RF; it does not receive like a radio.

  56. 56. Where does the dip meter’s other name, grid-dip oscillator (GDO), come from?
    Show answer

    Valve versions showed a dip in their grid current

    In old valve dip meters the grid current fell when a nearby tuned circuit drew energy from the oscillator, hence the name. The anode current does the opposite: it rises at the dip.

  57. 57. What is a dip meter used to find?
    Show answer

    The frequency at which a tuned circuit or antenna resonates

    A dip meter finds the frequency at which a tuned circuit or antenna resonates: its reading dips where the circuit takes energy from its oscillator. SWR at the antenna is a job for an antenna analyser.

  58. 58. A dip meter is coupled to a tuned circuit of 2,2 µH and 220 pF. Which is nearest to the frequency of the dip?
    Show answer

    7 MHz

    f = 1 ÷ (2π√LC) = 1 ÷ (2π × √(2,2 × 10⁻⁶ × 220 × 10⁻¹²)) = 1 ÷ (2π × 2,2 × 10⁻⁸) = 7,23 MHz, nearest 7 MHz. Leaving out the 2π gives 45 MHz.

    Try it: Reactance & Resonance
  59. 59. How is a dip meter coupled to the circuit under test?
    Show answer

    It is not wired in at all: its coil is held close to the circuit’s coil

    The dip meter’s plug-in coil sits outside its case so that it can be brought near the circuit, and energy couples across magnetically. Wiring it in would load and detune its oscillator.

  60. 60. Which description fits a dummy load?
    Show answer

    A resistor that absorbs a transmitter’s output without radiating it

    A dummy load is a non-inductive resistor, normally of 50 Ω, that turns the transmitter’s whole output into heat and radiates nothing. Cutting the power on its way to an antenna would be an attenuator’s job.

  61. 61. Which accessory replaces the antenna when a transmitter is tested without putting a signal on the air?
    Show answer

    A dummy load

    A dummy load takes the antenna’s place and turns the transmitter’s power into heat, so nothing is radiated. An attenuator only reduces the power and still needs a load after it.

  62. 62. Why should a transmitter feed a dummy load while it is being adjusted?
    Show answer

    So that it can be adjusted without radiating a signal

    A dummy load lets you test and adjust a transmitter off the air: radiating needlessly wastes spectrum and is poor operating practice. The good match it gives is a side benefit, not the reason.

  63. 63. Which component is suitable as the heart of an RF dummy load?
    Show answer

    A non-inductive resistor

    A dummy load must look like a pure resistance at RF, so a non-inductive resistor is used. Most resistors made for high power are wirewound, and their inductance makes them unsuitable.

  64. 64. Why is a wirewound power resistor a poor choice for a home-built RF dummy load?
    Show answer

    Its coiled wire has too much inductance at RF

    The coiled resistance wire gives the resistor considerable inductance, so at RF it no longer looks like a plain resistance. Such resistors handle plenty of power, which is why they tempt builders.

  65. 65. Why do practical high-power dummy loads have cooling fins, fans or an oil bath?
    Show answer

    To carry off the heat they produce while in use

    All of the transmitter’s output turns into heat in the resistor, so big loads need fins, fans, oil or a mix of these. A plain resistor needs no tuning for each band, and it stores nothing.

  66. 66. Which parts make up a simple field strength meter?
    Show answer

    A short antenna, a diode to detect RF, and a sensitive meter

    A simple field strength meter has only a short antenna, a detecting diode and a sensitive microammeter. With a tuned circuit added it becomes frequency selective: an absorption wavemeter.

  67. 67. What might you use a simple field strength meter for?
    Show answer

    Comparing how an antenna radiates in each direction

    Kept at one spot while the antenna turns, a field strength meter shows how strongly the antenna radiates each way: its directivity and rough gain. Its readings are only relative, so it cannot give power in watts.

  68. 68. A simple field strength meter swings up near your 14 MHz antenna. Why can it NOT tell you that the signal is on 14 MHz?
    Show answer

    It responds to RF across a very wide frequency range

    A simple field strength meter has no tuned circuit, so it is not frequency selective and reacts to RF across a wide range. A tuned version, the absorption wavemeter, can give a rough frequency.

  69. 69. Which statement about the readings of a simple field strength meter is most correct?
    Show answer

    They are only relative: good for comparisons, not true field strengths

    A simple meter’s uncalibrated antenna and diode give readings to compare, such as one direction against another. True field strength needs a calibrated receiver and antenna, normally in a laboratory.

  70. 70. A simple field strength meter shows nothing 300 m from a 10 W station whose signal is strong on a receiver there. What is the likely reason?
    Show answer

    Such meters are insensitive and need intense fields

    Simple field strength meters are not very sensitive, so they need a strong field and are used close to the antenna. A diode detector responds to an FM carrier as readily as to any other.

  71. 71. How does an absorption wavemeter differ from a simple field strength meter?
    Show answer

    It adds a tuned circuit, so it responds to one band at a time

    An absorption wavemeter is in effect a field strength meter with a tuned circuit added to pick the frequency. Its tuning is broad, so it gives only an approximate frequency, never an exact one.

  72. 72. Why can an absorption wavemeter give only the approximate frequency of a signal?
    Show answer

    Its tuned circuit is not very selective

    The wavemeter’s tuned circuit is broad, so the meter peaks over a spread of dial settings and points only to the rough frequency. The meter’s accuracy affects the size of the reading, not the frequency.

  73. 73. A transmitter works on 7,05 MHz. An absorption wavemeter also shows energy near 21,15 MHz. What is it?
    Show answer

    The third harmonic of the transmitter

    21,15 ÷ 7,05 = 3, so the energy is at three times the operating frequency: the third harmonic. The second harmonic would be near 2 × 7,05 = 14,1 MHz.

  74. 74. What is an absorption wavemeter especially useful for?
    Show answer

    Checking whether a transmitter radiates harmonics

    Tuned to two or three times the operating frequency, a wavemeter shows whether a transmitter radiates harmonics; energy near 7 MHz from an 80 m transmitter is the manual’s example. It gives no accurate power reading.

  75. 75. How can truly accurate field strength measurements be made?
    Show answer

    With a calibrated receiver and antenna, in a laboratory

    Meaningful figures need a calibrated measuring receiver and a calibrated antenna, normally in a laboratory such as an anechoic chamber. A simple meter, however carefully placed, gives only relative readings.

  76. 76. Which audio test signal is fed into an SSB transmitter to check its linearity and peak envelope power?
    Show answer

    Two tones of equal amplitude, not harmonically related

    A two-tone generator gives two audio tones, equal in amplitude and not harmonically related, for the microphone input. A tone and its exact second harmonic are harmonically related.

  77. 77. What can a two-tone test show about an SSB transmitter?
    Show answer

    Its peak envelope power output

    With its fixed 2:1 peak-to-average ratio, a two-tone signal lets a wattmeter reading true average power, with an oscilloscope, give the PEP; the pattern also shows linearity. Deviation and modulation index belong to FM.

  78. 78. During a two-tone test, a wattmeter reading true average power shows 60 W at the transmitter’s output. What is the peak envelope power?
    Show answer

    120 W

    A two-tone signal’s peak-to-average power ratio is exactly 2:1, so PEP = 2 × 60 = 120 W. Multiplying by 1,414 confuses a voltage ratio with a power ratio.

    Try it: dBm, Watts & dB
  79. 79. You want a linear amplifier to give at most 500 W PEP. With a two-tone signal applied, which is nearest to the true average power the wattmeter should show when the drive is set?
    Show answer

    240 W

    With two tones PEP is twice the average: 500 ÷ 2 = 250 W, so 240 W is nearest and keeps the PEP under 500 W. Dividing by 1,414 gives 354 W and would overdrive it.

    Try it: dBm, Watts & dB
  80. 80. Why can the PEP of a speech signal NOT be worked out from its average power?
    Show answer

    Its peak-to-average ratio varies with the voice and the moment

    The ratio of peak to average power differs greatly between voices and from one moment to the next, so no fixed factor turns an average reading into PEP. Brief peaks still set the PEP.

  81. 81. On a two-tone test, the rounded tops of the output pattern are cut off flat. What does this show?
    Show answer

    The transmitter is being overdriven

    Flat-topping, with the rounded tops and bottoms of the envelope chopped off, means the transmitter is overdriven; turn the drive down. Wrong bias shows instead as gaps where the loops should meet.

  82. 82. On a two-tone test, successive loops of the output pattern fail to join smoothly, leaving a gap between them. What is wrong?
    Show answer

    The amplifier is incorrectly biased

    Gaps where the loops should meet mean the amplifier is incorrectly biased, so it does not conduct properly near zero. Overdriving shows instead as flattened tops.

  83. 83. What kind of distortion does an SSB transmitter produce when it is non-linear?
    Show answer

    Intermodulation distortion, which must be cured before going on air

    A non-linear SSB transmitter produces intermodulation distortion, products that spread close around the signal, so the fault must be fixed before going on air. A low-pass filter cannot remove products that close.

  84. 84. Which instrument gives a more accurate check of an SSB transmitter’s linearity than a two-tone test pattern?
    Show answer

    A spectrum analyser

    A spectrum analyser separates the signal’s frequencies and shows the strength of each, so distortion products show up directly. A peak-reading wattmeter gives the PEP, not the linearity.

  85. 85. With a two-tone input, what does a linear SSB transmitter’s output pattern look like?
    Show answer

    Smooth, rounded loops that meet at zero between them

    A linear transmitter turns two equal tones into an envelope of smooth, rounded loops that touch zero between them, as in the figure on p282. A steady band is what a single tone gives.